{"product_id":"piusi-pump-240v-ac-56lpm-panther-ex56-f00580030","title":"PIUSI PUMP 240V AC 56lpm Panther EX56 · F00580030","description":"\u003ch2\u003ePIUSI PUMP 240V AC 56lpm Panther EX56 · F00580030\u003c\/h2\u003e\n\u003cp\u003eATEX Zone 1 cast-iron transfer pump. 56 lpm at 240V AC, continuous duty, feet-mounted. Suits petrol, diesel, kerosene in hazardous-area installations.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eATEX II 2 G Ex d IIA T4 Gb explosion-proof rating for Zone 1 hazardous areas\u003c\/li\u003e\n\u003cli\u003e56 l\/min continuous duty at 240V AC, 500W single-phase motor\u003c\/li\u003e\n\u003cli\u003eCast-iron pump body with sintered-steel rotor and Viton seals\u003c\/li\u003e\n\u003cli\u003eMagnetic ON\/OFF switch and integrated bypass valve\u003c\/li\u003e\n\u003cli\u003e1\" BSP inlet and outlet for standard fuel-line plumbing\u003c\/li\u003e\n\u003cli\u003eSuitable for diesel, petrol, and kerosene\u003c\/li\u003e\n\u003cli\u003eRemovable feet for permanent bolt-down installation\u003c\/li\u003e\n\u003cli\u003e12-month Piusi manufacturer warranty plus ATEX\/IECEx certificate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF00580030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanther EX 56 (Feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePump Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf-priming vane with bypass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e56 l\/min (14.7 GPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230V \/ 50Hz (compatible 240V AU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRPM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eATEX Marking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eII 2 G Ex d IIA T4 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuty Cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous (S1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInlet Thread\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\" BSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlet Thread\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\" BSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitch\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnetic ON\/OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCast iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRotor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSintered steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVanes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTechnopolymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eViton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShaft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFeet (removable, bolt-down)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFluid Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiesel, petrol, kerosene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePackaging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 x 240 x 300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eItaly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat's the difference between the Panther 56 and the Panther EX 56?\u003c\/h4\u003e\n\u003cp\u003eThe Panther 56 is rated for diesel only. The Panther EX 56 carries ATEX II 2 G certification for petrol, kerosene, and other flammable liquids in Zone 1 \/ Zone 2 hazardous areas. Same pump architecture, hardened for hazardous service.\u003c\/p\u003e\n\u003ch4\u003eIs this the feet or drum version?\u003c\/h4\u003e\n\u003cp\u003eFeet version (F00580030). Comes with removable mounting feet for bolt-down installation. The drum version (F00580010 in Piusi's catalogue) ships with a drum connector and nozzle holder for IBC \/ 200L drum mounting - speak to us if that's what you need.\u003c\/p\u003e\n\u003ch4\u003eWhy ATEX for diesel?\u003c\/h4\u003e\n\u003cp\u003eDiesel itself is not flagged as Zone 1, but if you're sharing a yard, workshop, or storage area with petrol or other flammable hydrocarbons, your hazardous-area classification may require ATEX-certified equipment across the whole installation. Many WHS-conscious sites standardise on ATEX as a future-proofing measure.\u003c\/p\u003e\n\u003ch4\u003eDoes it run continuously or have a duty cycle?\u003c\/h4\u003e\n\u003cp\u003eContinuous duty (S1). You can run it back-to-back for shift-long fills without thermal cut-out, unlike the Cube cabinet dispensers which have a 30-minute on\/off cycle.\u003c\/p\u003e\n\u003ch4\u003eWhat flow meter pairs with it?\u003c\/h4\u003e\n\u003cp\u003eFor ATEX-compliant metering, pair with the Piusi K600 ATEX or K33 ATEX mechanical meter. Non-ATEX meters cannot legally be used in the same Zone 1 installation.\u003c\/p\u003e\n\u003ch4\u003eDoes it come with a nozzle and hose?\u003c\/h4\u003e\n\u003cp\u003eNo - this is the pump-only version. Speak to us about matched ATEX-rated nozzles, hoses, and suction kits to build a complete petrol or diesel transfer station.\u003c\/p\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 12.4 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFreight:\u003c\/strong\u003e Carton\u003c\/li\u003e\n\u003cli\u003eShips from Brisbane in original Piusi packaging. 400 x 240 x 300 mm carton.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0015\/0090\/5590\/files\/PIUSI_PUMP_240V_AC_56lpm_Panther_EX56_F00580030_-_iFUEL_-_Data_Sheet.pdf?v=1779668017\" title=\"Data Sheet - PIUSI PUMP 240V AC 56lpm Panther EX56 · F00580030\" target=\"_blank\" rel=\"noopener\"\u003eDATA SHEET\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor technical enquiries, installation or commissioning support, contact iFUEL at \u003ca href=\"mailto:sales@ifuel.com.au\"\u003esales@ifuel.com.au\u003c\/a\u003e or call \u003ca href=\"tel:0732042240\"\u003e07 3204 2240\u003c\/a\u003e.\u003c\/p\u003e","brand":"iFUEL® Refuelling Solutions","offers":[{"title":"Default Title","offer_id":47902510284974,"sku":"F00580030","price":1276.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0015\/0090\/5590\/files\/piusi-panther-ex-56-atex-fuel-pump-240v-ac-56lpm-8712955.jpg?v=1779662043","url":"https:\/\/ifuel.com.au\/products\/piusi-pump-240v-ac-56lpm-panther-ex56-f00580030","provider":"iFUEL® Refuelling Solutions","version":"1.0","type":"link"}